PMP-116 level indicator
Indication (5 .. 95%) tanks filling with resolution ≈10%. Transport tank application. Self-contained power supply from built-in power source.
  • Info
  • Specifications

Specifications

Number of control levels11
Guide pipe length, mm, not more than6 000;
2 500 (for transport mod.);
5 000 (mod. with increased resistance to corrosive media)
Volume indication step, %10; 5 – at extreme points of range
Minimal level presetting step, mm10
Limits of control level setting tolerance, mm±2
Case materialsteel 09G2S, steel 12Cr18Ni9Ti (cast housing), 12Cr18Ni10Ti (welded housing) - as per Customer's request
Material of guide pipesteel 12Cr18Ni10Ti
Monitored media featurestemperature, ℃from -50 to +100 (up to +125 – on order);
from -50 to + 80 – for modification with increased resistance to corrosive media
pressure, MPa, not more than2.5; 10 – on order
density, kg/m³, not less than
Климатическое исполнение по ГОСТ 15150
Operation temperature, ℃from -50 to +60
Water and dust ingress protection degree as per IEC 60529IP66
Explosion protection marking
Power sourcelithium battery, type CR123
Power supply voltage (Up), V3
Battery replacement period, years3
Weight, kg, not more than25
Service life, years10