- Info
- Specifications
- Downloads 1
Specifications
Nominal diameter (DN), mm | 10 | 15 | 20 | ||||
---|---|---|---|---|---|---|---|
Effective diameter, mm | 10 | 15 | 20 | ||||
Nominal pressure (PN), kgf/cm² | 250 | ||||||
Pressure difference (ΔP) for direct thrust, kgf/cm² | from 0 to 250 | ||||||
Pressure difference (ΔP) for inverted thrust, kgf/cm² | not applied 1) | ||||||
Working pressure, kgf/cm² | 320 | ||||||
Closing mechanism sealing according to GOST R 54808 | «A» class | ||||||
Case material | steel 14Kh17N2 | ||||||
Time of closing mechanism opening / closing, s, not more than | 1 / 1 | ||||||
Supply voltage |
| ||||||
Consumed power (PF / PHold), W |
| ||||||
Operation length, % | 100 | ||||||
Activation frequency, cycle/min, not more than | 6 | ||||||
Operational media temperature, ℃ | from -50 to +80 (short-time operation up to 100) | ||||||
Ambient temperature, ℃ | from -50 (from -60 - on order) to +60 | ||||||
Explosion protection marking | non-electrical part: 1Ex h IIC T6 Gb X; actuator: 1Ex db IIC T4 Gb X | ||||||
Orientation on the pipeline | with drive facing up ±90° | ||||||
Process connection | G1/2 2) | G3/4 2) | G1 2) | ||||
Overall dimensions, mm | A, not more than | 217 | 217 | 217 | |||
C, not more than | 154 | 154 | 154 | ||||
C | 72 | 72 | 72 | ||||
Weight, kg, not more than | 10 | ||||||
Full service life, years | 40 | ||||||
Notes. 1) When pressure is supplied in the opposite direction, the valve will be opened. 2) Threaded coupling connection in accordance with GOST 22526-77 (other – on order) |