PMP-115, PMP-125, PMP-135, PMP-145 level indicators with W5DNC output
Application
Level sensors, having W5DNC output are used in combination with MS-3-type signal device; The sensors are designed to control the limit levels of water in light petroleum products, oil in one or several (up to four) points in tanks with depth up to 30 meters. Might be also used with other media: food, agressive, and poisonous.
Design, principle of operation
Level sensor consists of:
- from one up to four probes, each of which has one or two floats with magnet
- guiding two-wire screened cable in fluoroplastic sheaths, connecting probes
- Connecting muff, designed for connection of control cable of MS-3 signal device… to a guiding cable
- housing, designed for sensor fixture on the top side of the tank
The PCB with reed switches is placed inside the probe.
PMP operation principle is based on magnet contact state (closed or open) altering under floating magnet impact, thus, the electrical conductivity of the diode circuit is being altered: electric current may flow in both directions, in one direction or not flow at all.
Electrical conductivity altering is recorded by MS signal device, which: alters the light indication, switches the relay terminals, switches on the sound signal.
Technical parameters
No.
|
Parameter
|
Level sensor parameter value |
||||
PMP115 |
ПМП-125 |
ПМП-135 |
ПМП-145 |
|||
1 |
Control levels |
N, V, N-V |
ND*-N-V-VD* |
VA-V-N, NA-N-V, V-VA, NA-N |
NA-N-V,N-V-VА |
|
2 |
Probes quantity |
1 or 2 |
4 |
1 |
2 |
|
3 |
Probe pipe length, mm |
154 |
154 |
250-3000 |
154(250-700) |
|
4 |
Measured level range, м |
From 0,1 up to 30 |
||||
5 |
Inaccuracy of control level value setting, mm |
±10 |
||||
6 |
Ambient temperature, °С |
from minus 50 up to 60 |
||||
7 |
Monitored medium pressure |
atmospheric |
||||
8 |
Water and dust protection: Probe Housing Connection muff |
IP68 IP66 IP67 |
||||
9 |
УХЛ1*, (in range from 50 up to 60 °С) |
|||||
10 |
Explosion protection marking |
0Ex ia IIB T6 Ga (Ga/Gb Ex ia IIB T6) |
||||
11 |
Service life, years |
10 |
Notes